INSTALLATION

 

 

Connection of the LN-7 to the Ranger 8

Welder Operation

 

 

• Shut the welder off.

Welder Output

 

 

 

 

 

• Connect the LN-7 and the K240 contactor kit per

Maximum Open Circuit Voltage at 3700 RPM is

 

instructions on the connection diagram S17742

 

(can be found in the back of this manual).

 

80 Volts RMS.

 

 

• Place the “RANGE” switch to the “WIRE FEED”

Duty Cycle: 100% for both welding and auxiliary

 

position and the “POLARITY” switch to the

 

power.

 

 

desired polarity.

 

 

 

 

 

 

 

 

Ranger 8

 

 

 

 

 

 

• Place the “IDLER” switch in the “HIGH” idle

 

 

 

 

 

Constant Current

 

225 Amps AC @ 25 Volts

 

position. The engine idling device may not

 

 

 

 

 

210 Amps DC @ 25 Volts

 

function when welding in the “WIRE FEED” mode.

 

 

 

 

 

 

 

 

 

• Adjust wire feed speed at the LN-7 and adjust the

Constant Voltage

 

200 Amps DC @ 20 Volts

 

 

 

 

 

 

welding voltage with the output “CONTROL” at

 

 

 

 

 

 

 

 

 

 

the welder.

Auxiliary Power

 

 

NOTE: If the output “CONTROL” is set below “3” the

 

 

 

 

 

K240 contactor may not pull in.

The Ranger 8 can provide up to 8,000 watts of 115/230

 

 

 

Connection of K930-[ ] TIG Module to the

volts AC, single phase 60Hz power for continuous use.

 

The front of the machine includes three receptacles for

 

Ranger 8.

connecting the AC power plugs; one 50 amp 115/230

 

 

volt NEMA 14-50R receptacle and two 20 amp 115 volt

 

The TIG Module is an accessory that provides high

NEMA 5-20R receptacles.

 

frequency and shielding gas control for AC and DC

 

 

 

 

 

GTAW (TIG) welding. See IM528 supplied with the

 

 

 

 

 

TIG Module for installation instructions.

 

 

 

 

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Note: The TIG Module does not require the use of a high frequency bypass capacitor. However, if the Ranger 8 is used with any other high frequency equip- ment, the bypass capacitor must be installed - order kit T12246.

INSTRUCTIONS

Additional Safety Precautions

Always operate the welder with the roof and case sides in place as this provides maximum protection from moving parts and assures proper cooling air flow.

Read and understand all Safety Precautions before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Owner’s Manual.

CAUTION

Do not connect any plugs that connect to the power receptacles in parallel.

------------------------------------------------------------------------

Start the engine and set the “IDLER” control switch to the desired operating mode. Set the “CONTROL” to

10.Voltage is now correct at the receptacles for auxil- iary power.

115/230 Volt Dual Voltage Receptacle

The 115/230 volt receptacle can supply up to 40 amps of 230 volt power to a two wire circuit, up to 40 amps of 115 volts power from each side of a three wire cir- cuit (up to 70 amps total). Do not connect the 115 volt circuits in parallel. Current sensing for the automatic idle feature is only in one leg of the three wire circuit as shown in the following column.

RANGER 8

Page 13
Image 13
Lincoln Electric SVM107-B Connection of the LN-7 to the Ranger, Welder Output, Constant Current, Constant Voltage