TROUBLESHOOTING & REPAIR
NORMAL OPEN CIRCUIT DC WELD VOLTAGE WAVEFORM (CC MODE)
HIGH IDLE - NO LOAD - OUTPUT CONTROL AT MAXIMUM
CH1
0 volts
50 volts | 5 ms |
This is the typical DC output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.
Note: Scope probes connected at machine output terminals.
SCOPE SETTINGS
Volts/Div | 50V/Div. |
Horizontal Sweep | 5 ms/Div. |
Coupling | DC |
Trigger | Internal |
|
|