Linksys SFE2010P manual Rack-Mount Placement

Models: SFE2010 SFE2010P

1 67
Download 67 pages 1.69 Kb
Page 10
Image 10

Connecting Devices

Placement Options

CAUTION: Keep enough ventilation space for the Ethernet switch so it does not exceed the environmental restrictions mentioned in the specifications.

Rack-Mount Placement

To mount the Ethernet switch in any standard-sized, 19-inch wide, (each Ethernet switch requires 1RU of space in the rack), follow these instructions:

1.Remove the four front screws on one side of the Ethernet switch. Retain the screws for re- installation.

2.Place one of the supplied spacers on the side of the Ethernet switch so the four holes align to the screw holes.

3.Place a rack mount bracket next to the spacer and reinstall the four screws (removed in step 1).

4.Repeat steps 2 through 3 for the other side of the Ethernet switch.

5.Attach the Ethernet switch to the rack using the supplied screws.

SFE2010/SFE2010P Administration Guide

7