Lochinvar 1.3 Inspect ignition and flame sense electrodes, Check ignition ground wiring

Models: 1.3 1

1 56
Download 56 pages 40.75 Kb
Page 39
Image 39
Inspect ignition and flame sense electrodes

2 Maintenance (continued)

Inspect ignition and flame sense electrodes

1.Remove the ignition and flame sense electrodes from the boiler heat exchanger access cover.

2.Remove any deposits accumulated on the ignition/flame sense electrode using sandpaper. If the electrodes cannot be cleaned satisfactorily, replace with new ones.

3.Replace ignition/flame sense electrode, making sure gasket is in good condition and correctly positioned.

Check ignition ground wiring

1.Inspect boiler ground wire from the heat exchanger access cover to ground terminal strip.

2.Verify all wiring is in good condition and securely attached.

3.Check ground continuity of wiring using continuity meter.

4.Replace ground wires if ground continuity is not satisfactory.

Check all boiler wiring

1.Inspect all boiler wiring, making sure wires are in good condition and securely attached.

Check control settings

1.Go to the Setup Screen and check all settings. See Section

1of this manual. Adjust settings if necessary. See Section

1of this manual for adjustment procedures.

2.Check settings of external limit controls (if any) and adjust if necessary.

Perform start-up and checks

1.Start boiler and perform checks and tests specified in Section 9 - Start-up of the SYNC Installation and Operation Manual.

2.Verify cold fill pressure is correct and that operating pressure does not go too high.

Service Manual

Check burner flame

1.Inspect flame through observation window.

2.If the flame is unsatisfactory at either high fire or low fire, turn off boiler and allow boiler to cool down. Remove the burner and clean it thoroughly using a vacuum cleaner or compressed air. Do not use compressed air to clean burner if performed inside a building.

3.Remove the burner, reference FIG. 2-2.

4.When replacing the burner, ensure gasket is in good condition and positioned correctly (FIG. 2-2).

Figure 2-2Burner Assembly

DOOR FIBER

 

BURNER DOOR

 

 

BURNER DOOR

 

 

HEX NUT (6)

 

 

BURNER

 

AIR/GAS GASKET

 

 

FLAPPER VALVE

 

IGNITER GASKET

SCREW (5X)

IGNITER

FLAME SENSE

 

FLAPPER VALVE

 

 

GASKET

 

FLAME SENSE

 

IGNITER SCREW (2X)

 

FLAME SENSE

 

 

SCREW (2X)

 

Check ignition ground wiring 39 Check all boiler wiring

Page 39
Image 39
Lochinvar 1.3 Inspect ignition and flame sense electrodes, Check ignition ground wiring, Check all boiler wiring