Prepare wall penetrations

Installation & Operation Manual

3 Sidewall direct venting

Figure 3-3BAlternate Clearance to Forced Air Inlets w/ Field Supplied Fittings

8. PVC/CPVC terminations are designed to accommodate any

wall thickness of standard constructions per the directions

found in this manual.

7’ (2.1 M) MIN ABOVE ANY

PUBLIC WALKWAY

IF LESS

THAN 10’ (3 M)

36” (914 MM)

MIN

FORCED AIR

INLET

BIRD

SCREEN

(TYPICAL)

9. Stainless steel terminations are designed to penetrate walls

with a thickness up to 9.25 inches of standard construction.

Figure 3-4APVC/CPVC Sidewall Termination Assembly

 

VENT AIR

AIR PIPING

CENTERLINE WIDTH

VENT PIPING

 

 

VENT PLATE

WALL PLATE

VENT CAP

 

Prepare wall penetrations

1.Use the factory supplied wall plate as a template to locate the vent and air intake holes and mounting holes.

Air pipe penetration:

a.Cut a hole for the air pipe. Size the air pipe hole as close as desired to the air pipe outside diameter.

Vent pipe penetration:

a. Cut a hole for the vent pipe. For either combustible

or noncombustible construction, size the vent pipe

hole with at least a 1/2 inch clearance around the

vent pipe outer diameter:

• 7½ inch hole for 6 inch vent pipe

• 8½ inch hole for 7 inch vent pipe

GALVANIZED

THIMBLE

Table 3C Sidewall Vent Centerline Dimensions

Model

Air

Vent

Centerline Width

 

 

 

 

All

6"

6"

7 3/4"

Figure 3-4BPolypropylene Sidewall Termination Assembly

Drill 3/16" diameter holes for inserting the plastic anchors into the wall.

2.

For Polypropylene Only: Install the vent and air intake

 

sidewall adapters from Table 2E on page 20 into the vent

 

plate. Slide the sidewall retaining bracket down the

 

sidewall adapters flush to the vent plate (FIG. 3-4B).

3.

For PVC/CPVC Only: Install the vent and air intake

 

piping through the wall into the vent plate openings.

 

Use RTV silicone sealant to seal the air pipe. Use the

 

cement/primer listed in Table 2C on page 19 to seal the

 

vent pipe.

4.

Mount and secure the vent plate to the wall, using stainless

 

steel screws.

5.

Seal all gaps between the pipes and wall. Seal around the

SIDEWALL ADAPTER (AIR)

SIDEWALL ADAPTER (VENT)

WALL

PLATE

SIDEWALL

RETAINING

PLATE

VENT

PLATE

VENT

CAP

 

plate to the wall assuring no air gaps.

6.

Assemble the vent cap to the vent plate (see FIG.’s 3-4A

 

and 3-4B). Insert the stainless steel screws into the vent

 

cap screw hole openings and securely attach the vent cap

 

to the vent plate.

7.

Seal all wall cavities.

GALVANIZED

IMG00085

THIMBLE

 