6 Hydronic piping (continued)

Figure 6-11Single Boiler - Multiple Temperatures with DHW Piped as a Zone

TEMPERATURE

TEMPERATURE

LOOP 3

TEMPERATURE

LOOP 2

 

LOOP 1

 

 

AIR SEPARATOR

PRESSURE

GAUGEBALL VALVE (TYPICAL)

MAKE UP WATER

 

 

EM

 

ST

TO

SY

 

 

 

 

 

EM

 

ST

OM SY

 

FR

 

 

Y-STRAINER (RECOMMENDED)

BACK FLOW

PREVENTER

PRESSURE REDUCING

VALVE

DRAIN POINT (TYPICAL)

EXPANSION

TANK

PRESSURE RELIEF VALVE

FLOW CHECK VALVE (TYPICAL)

BOILER CIRCULATOR

INDIRECT DHW

 

 

TANK

 

 

HOT WATER OUT

 

 

ANTI-SCALD

UNION (TYPICAL)

 

MIXING VALVE

DRAIN

 

COLD WATER IN

 

DOMESTIC

TEMPERATURE / PRESSURE

 

HOT WATER

BOILER

CIRCULATOR

GAUGE

 

CAUTION

CAUTION

NOTICE

NOTICE

Indirect water heaters are capable of transferring a limited number of Btu’s into the water. Ensure boiler output does not not exceed indirect water heater transfer capabilities.

Mixing valves are required for the protection of low temperature loops.

Please note that these illustrations are meant to show system piping concept only, the installer is responsible for all equipment and detailing required by local codes.

Please note that the installer is responsible for ensuring DHW prioritization when piped as a zone.