Installation & Operation Manual

11 Operating information (continued)

Figure 11-2Status Display Screen

A

(BOILER

STATUS)

C

(OPERATIONAL

INFORMATION)

D

(LEFT SELECT

KEY)

E

B

(CALL FOR

HEAT)

F

(RIGHT SELECT KEY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(NAVIGATION DIAL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status Display Screens

Section

 

 

Display

 

Description

 

 

 

STANDBY

 

The unit has not received a call for heat from a remote thermostat nor

 

 

 

 

has it received a call for heat from a DHW thermostat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

START

 

The unit has begun a burn cycle and is checking all safety circuits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PREPURGE

 

The unit has initiated a 10 second purge period on a call for heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IGNITION

 

The unit has begun a 4 second spark period to ignite the main burner.

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

%

 

 

 

 

 

 

 

The unit has fired and is running at the displayed percentage.

(Boiler Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The call for heat has been satisfied and the unit runs the fan for an

Bar)

 

 

POSTPURGE

 

additional 10 seconds to clear the combustion chamber and vent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

system of residual flue products.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUTDOWN

 

The unit has been placed in the OFF position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The controlled temperature has exceeded its set point and its offset.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOCKED

 

The unit has detected a condition that has temporarily interrupted

 

 

 

 

the current call for heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Room Thermostat 1 has a call for heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Room Thermostat 2 has a call for heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Room Thermostat 3 has a call for heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Call for Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The tank thermostat or sensor has a call for heat.

Indicators)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates which room thermostat demand shows priority.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The unit is being controlled by a 0 - 10V BMS signal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The member unit is supplying heat while in Cascade Mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

69

Page 69
Image 69
Lochinvar 400, 801 operation manual Call for Heat

400, 801 specifications

The Lochinvar 801,400 is a cutting-edge solution in the realm of high-efficiency commercial water heating. This model represents a significant advancement in the design and functionality of water heaters, catering primarily to the demands of large-scale facilities like hotels, hospitals, and large industrial operations.

One of the standout features of the Lochinvar 801,400 is its impressive heating capacity, which can produce up to 801,400 BTUs, making it suitable for high-demand applications. This output is crucial for establishments that require a consistent supply of hot water, such as commercial kitchens and laundry facilities. The robust design ensures that it can handle peak demand periods without compromising performance.

Another significant aspect is the innovative use of advanced technology in its operation. The Lochinvar 801,400 integrates smart controls that enhance its efficiency and ease of operation. These controls allow for precise monitoring and adjustment of water temperatures, ensuring that the system operates within optimal parameters while maximizing energy savings. The intelligent monitoring system can provide real-time updates, making it easier for facility managers to keep track of performance and address maintenance needs proactively.

The construction of the Lochinvar 801,400 incorporates durable materials that not only enhance the longevity of the unit but also offer resistance to corrosion and wear. This durability translates into lower maintenance costs and an extended lifespan for the unit, making it a worthwhile investment for businesses.

Moreover, the Lochinvar 801,400 is designed with energy efficiency in mind. It boasts a high thermal efficiency rating, which reduces operational costs and minimizes the carbon footprint of heating operations. This efficiency is critical in today’s environmentally conscious market, where businesses are seeking to reduce their energy consumption and comply with strict regulations.

The design of the Lochinvar 801,400 also prioritizes safety, featuring innovative safety controls and fail-safes that protect both the unit and the users.

In summary, the Lochinvar 801,400 offers a combination of high capacity, advanced technology, durability, and energy efficiency, making it an excellent choice for commercial water heating solutions. As industries continue to evolve, the demand for reliable and efficient water heating solutions like the Lochinvar 801,400 will only increase.