Log Installation

Finalizing the Installation (for qualified installers only) 2 1

Log Installation

!Make sure the gas control valve is “OFF” and the heater is cool prior to conducting service.

!Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

Place the rear log so it rests against the ledge on the back wall of the firebox.

Push on the outer edges to

insure it sits up straight.

Note how it does not cover

any of the burner holes.

Align the edge of the

log with the edge of the burner.

NOTE: Rotate the front log so there is a 1/8” to 1/4” gap along the front of the log

Place the twig so the pin on the rear log inserts into the hole on the twig. NOTE: you may need to tilt the rear log forward to insert the pin.

1/8” - 1/4” Installing the Rock Wool:Front View of Logs

Installing the Rock Wool:

The rock wool comes in one clump. Tear off “dime” sized clumps and flatten. Then pull on the wool to create gauze-like pieces. Place them near some of the burner holes. The wool glows best when very thin and porous.

Front View of Logs

Place the embersManual backgroundManual backgroundManual backgroundManual backgroundManual background over the front andManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background side edges of the Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background burner in a random Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background pattern (do not place Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background them over the burner Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background holes).Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background