Installation Addenda | 4 1 |
ADDENDUM #2 Masonry Chimney
Interior Masonry Chimney
Conversions
• Follow the requirements and use |
the equipment listed in the |
illustration below to install this |
appliance into an interior masonry |
chimney. |
The entire chimney system must be
Make sure the coaxial pipe maintains a 1” clearance to any combustible. The vent must be sealed
#991 High Wind
Termination |
Flashing (included in |
#934 Masonry
Conversion Kit
Silicone .
• Maximum vertical rise is 40' | |
• | Minimum vertical rise is 10' |
• | See the chart on page 15 for |
| determining the correct restrictor |
| position. |
#990 90° Elbow | 4" Dia. Flex Line |
| (UL 1777 Gas Liner) |
Lengths
Connector with Cover
(included in #934 Masonry
Conversion Kit)
NOTE: these restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly
Standard Masonry Fireplace
The entire chimney system must be
.
Make sure the coaxial pipe maintains a 1” clearance to any combustible. The vent must be sealed
#991 High Wind
Termination |
Flashing (included in |
#934 Masonry |
Conversion Kit) |
4" Dia. Flex Line |
(UL 1777 Gas Liner) |
Connector (included in #934 Masonry Conversion Kit) secured and sealed to
Travis Industries | 1 0 0 - 0 1 1 4 2 | 4 0 5 0 1 1 4 |