Optional Equipment (for qualified installers only) 3 5

5Remove the regulator from the front of the gas control valve. Replace with the propane regulator, using the new gasket and screws included with the regulator. NOTE: Leak test this area after the heater is installed, gas is connected, and the main burner is lit.

a

c

Remove and discard the three screws using a slotted screwdriver of Torx T-20.

b

Remove and discard the regulator, diaphram, spring and center post.

Slotted

Screwdriver

(or T-20 Torx)

Install the LP regulator. Use the screws included with the LP regulator. Tighten to approximately 25 Lbs. torque.

NOTE: Make sure the regulator gasket is correctly aligned before installation.

Slotted

Screwdriver

(or T-20 Torx)

d

Place the LP label on top of the control cover near the gas control valve.

6Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak- test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.

WARNING: When lighting or re-lighting the pilot, the glass must be removed (see page 19).

To adjust the pilot flame, turn this screw (NOTE: if totally

 

The pilot flame must contact the thermocouple and

unscrewed gas will come out of this port). Clockwise

 

thermopile (see the illustration below). Adjust the pilot up or

lowers the flame while counter-clockwise raises it.

Standard

down as necessary.

 

Screwdriver

 

7Install the log set (see page 21).

8Replace the glass (see page 19).

Travis Industries

1 0 0 - 0 1 1 4 2

4 0 5 0 1 1 4

Page 35
Image 35