14 Installation (for qualified installers only)
Approved Venting Configurations for Horizontal Terminations
•12’ Maximum System Height
•15’ Maximum Offset
•The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.
•One 45° elbow may be used. It must be positioned horizontally (connecting one horizontal section or starter section to a horizontal section).
•If using a Snorkel Termination (14” or 36”) add the snorkel height to the vertical height (snorkel terminations are used primarily for basement installations).
0feet | 5feet | 10feet |
12' (max)
10 feet
Restrictor Position # 1
Remove Diffuser Plate
5feet
0feet
0feet | 5feet | 10feet |
' (max)
15 Restrictor Position # 5
Remove Diffuser Plate
12' (max)
10 feet
5 feet
Restrictor Position # 1
Keep Diffuser Plate
0 feet
15' (max)
Travis Industries | 1 0 0 - 0 1 1 4 2 | 4 0 5 0 1 1 4 |