2.3.1Electrical Characteristics
Table 2.3 lists the maximum power requirements and includes all of the LSI Logic 2 Gbit/s FC host adapter boards under normal operation.
Table 2.3 | Maximum Power Requirements | ||||
|
|
|
| ||
Host Adapter |
| PCI +3.3 V | Over the Operating Range | ||
|
|
| |||
4.7 W @ 3.6 V | 0 ˚C to 55 ˚C | ||||
|
|
| |||
4.7 W @ 3.6 V | 0 ˚C to 55 ˚C | ||||
|
|
| |||
6.5 W @ 3.6 V | 0 ˚C to 55 ˚C | ||||
|
|
| |||
6.5 W @ 3.6 V | 0 ˚C to 55 ˚C | ||||
|
|
|
| ||
11.5 | W @ 12.6 V | 0 ˚C to 55 ˚C | |||
|
|
|
|
| |
LSI7202EP |
| 10.7 | W @ 12.6 V | 0 ˚C to 55 ˚C | |
| plus SFP power, if any | ||||
|
|
| |||
|
|
|
|
| |
14.7 | W @ 3.6 V | 0 ˚C to 55 ˚C | |||
plus 4.2 W @ 5.25 V | |||||
|
|
| |||
|
|
|
| ||
16.0 | W @ 12.6 V | 0 ˚C to 55 ˚C | |||
|
|
|
|
| |
LSI7402EP |
| 14.4 | W @ 12.6 V | 0 ˚C to 55 ˚C | |
| plus SFP power, if any | ||||
|
|
| |||
|
|
|
|
|
2.3.2Thermal, Atmospheric Characteristics
The thermal, atmospheric characteristics of the LSI Logic 2 Gbit/s family of FC host adapters are:
•Temperature range: 0 ° C to 55 ° C (dry bulb), 100 linear feet per minute (LFPM) airflow minimum
•Relative humidity range: 5% to 90% noncondensing
•Maximum dew point temperature: 32 ° C
The following parameters define the storage and transit environment for the LSI Logic 2 Gbit/s family of FC host adapters:
• Storage Temperature: − 45 ° C to +85 ° C (dry bulb)
•Relative Humidity Range: 0% to 95%, noncondensing
Physical Environment |
Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.