Target 4

Unit 0 Disk SEAGATE ST39173FC 6258

WWN 210000203710324a Port ID 73

/pci@8,700000/scsi@6

Target 6

Unit 0 Removable Read Only device PLEXTOR CD-ROM PX-20TS

If the FC devices on your IntraServer™ adapter are not identified by your system, check the following:

Is the FC enclosure powered on?

Does the LED on the adapter indicate Link? (Note that Link is valid only after the device is probed.)

Does the LED on the switch or remote enclosure indicate Link?

Does the Link-SPEED parameter selected by the adapter match that of the bus (1G, 2G, or Auto)?

If you do not see disks, the following additional debug information may help to identify the problem.

4.7.3Verifying Installation

Use the following procedure to verify installation of your Fusion-MPT adapter in the system:

Step 1. Power-up the system.

Step 2. When the banner is displayed, press the STOP+A keys to interrupt the boot process and stop at the ok prompt.

Step 3. Use the show-devscommand to list the system devices. You should see an output similar to the following:

ok show-devs

/SUNW,UltraSPARC-III@0,0 /virtual-memory /memory@m0,0

/aliases

/options

/openprom

/chosen

/packages

OpenBoot BIOS

4-9

Copyright © 2002 - 2005 by LSI Logic Corporation. All rights reserved.