Field Name

Description

 

 

 

 

Clock Admin State

The administered clock synchronization state of the

 

M-SPS module. Possible states are:

 

enable - Clock synchronization is enabled on

 

the device.

 

disable, use Internal Clock - Clock

 

synchronization is disabled on the M-SPS

 

module. The M-SPS module uses its internal

 

low accuracy (±20 ppm) oscillator.

 

 

Clock Status

The status of clock synchronization on the device.

 

Possible statuses are:

 

locked - The M-SPS module is using a clock

 

which is locked to the input timing source.

 

holdover - The M-SPS module is simulating a

 

clock to which it was previously locked. This

 

state will last until the clock source is fixed.

 

free_running - The M-SPS module is using its

 

±4.6 ppm oscillator to generate timing. This only

 

occurs after a reset when there are no healthy

 

timing sources available or when all four

 

sources are configured with a priority of 0.

 

internal - Clock synchronization is disabled and

 

the M-SPS module is using its low accuracy

 

(±20 ppm) internal oscillator to generate timing.

 

 

Configuration Symbol

For Module Configuration: The version of the

 

module. The version is updated whenever there is a

 

functional modification to the module.

 

For Agent Configuration: The version of the

 

hardware and firmware of the agent.

 

 

Connected To

The DomainX to which the selected module is

 

connected - DomainXL for the left DomainX and

 

DomainXR for the right DomainX.

 

 

Current Source

The current source clock used for clock

 

synchronization. Possible sources are:

 

ATM A/B - An ATM port on the device.

 

SYNC A/B - An external source connected to the

 

front panel of the M-SPS.

 

none - No recognizable clock source.

 

 

66