Field Name

Description

 

 

 

 

Serial Number

A unique number assigned by Lucent Technologies

 

to the selected hardware.

 

 

Slot Number

The slot number in which the module is located.

 

Slots are numbered from left to right, starting with

 

number 1 as the leftmost slot.

 

This number may be 1 - 14. The agent module is

 

inserted in either slot 15 or 16. A module which

 

occupies two enclosure slots, will be identified by

 

the number of the second slot (the right-hand slot).

 

The slot number is the position in which the

 

module is located. There can be up to 5 modules in

 

a device. The Slot Number is set using the rotary

 

switch on the back panel of the device.

 

 

Source

The timing source whose parameters appear in the

 

table row. Possible sources are:

 

ATM A - An ATM port on the Cajun M770 ATM

 

switch.

 

ATM B - An ATM port on the Cajun M770 ATM

 

switch.

 

SYNC A - An external source connected to the

 

front panel of the M-SPS module.

 

SYNC B - An external source connected to the

 

front panel of the M-SPS module.

 

 

Source Port

The configured timing source port for clock

 

synchronization. The source port can be one of the

 

ATM ports on the Cajun M770 ATM switch or an

 

E1/T1 external source connected to the M-SPS

 

front panel. Suitable ATM ports/modules are:

 

• Ports 1 & 2 on M15-155 modules with C/S 2.0

 

or higher.

 

• All ports on M3-622 modules with C/S 1.0 or

 

higher.

 

 

Cajun M400 Manager User’s Guide

71

Page 61
Image 61
Lucent Technologies Cajun M770 manual Cajun M400 Manager User’s Guide