Lucent Technologies Cajun M770 manual Algorithm STA on page 27 of The Reference Guide

Models: Cajun M770

1 72
Download 72 pages 28.05 Kb
Page 62
Image 62

Field Name

Description

 

 

 

 

Source Priority

The priority of the timing source. The source with

 

the highest priority that is healthy will be selected

 

as the current source. The valid range of priorities

 

is:

 

disable - The source is disabled.

 

1 - 4 - 4 is the highest.

 

 

Source Status

The status of the timing source. Possible statuses

 

are:

 

ok - The timing source is healthy and is detected

 

on this source.

 

loss of signal - The timing source is not

 

detected on this source.

 

failed - The timing source is detected but is not

 

healthy.

 

 

Spanning Tree Algorithm

The state of Spanning Tree Protocol. Possible states

 

are:

 

Disabled - STA is disabled. This is the default

 

state.

 

Enabled - STA is enabled.

 

When activating STA, keep in mind that:

 

• All bridges should run STA.

 

• Redundancy applications and STA cannot co-

 

exist.

 

• The Security application and STA cannot co-

 

exist.

 

• STA can be activated in Cajun P110 only when

 

an agent module exists. Standalone modules

 

(including Cajun P113F and Cajun P117

 

Devices) cannot run STA.

 

For more information refer to Spanning Tree

 

Algorithm (STA) on page 27 of The Reference Guide.

 

 

System Contact

Individual responsible for maintenance of the

 

device.

 

 

System Description

A description of the type of system being used.

 

 

System Location

The physical location of the device.

 

 

72

Cajun M400 Manager User’s Guide

Page 62
Image 62