Configuration
3-35
9124-A2-LB20-00 March 2000
DSX-1 to Network Time Slot Assignment Screen Example (Page 1)
main/config/tslot_assign/dsx 9124
Device Name: Node A 5/26/1999 23:32
DSX-1 TO NETWORK 1 ASSIGNMENTS Page 1 of 2
N01 N02 N03 N04 N05 N06 N07 N08
D01-1/01 D01-1/02 D01-1/03 D01-1/04 Assigned Assigned Assigned Assigned
N09 N10 N11 N12 N13 N14 N15 N16
D01-1/09 D01-1/01 Available Available Available Available Available Available
N17 N118 N19 N20 N21 N22 N23 N24
Available Available Available Available Available Available Available Available
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Save PgDn PgUp ClearAll FrAssign
Page 2 of 2 is for defining signaling assignments and trunk conditioning for each
DSX-1 interface time slot. See DSX-1 Signaling Assignments and Trunk
Conditioning for an example of this screen.
For easy movement between screens, select the FrAssign function key to go
directly to the Frame Relay Network Assignments screen.
Time Slot Assignment Rules:
HValid Network time slots are either Available or contain a DSX-1 time slot
assignment.
HValid DSX-1 time slots are those that are unassigned, including the currently
assigned time slot.
HOrder of display is as follows:
Available is the first selection.
Then, from the lowest DSX-1 interface to the highest DSX-1 interface.
Then the lowest available time slot number to the highest available time
slot number.
For example, if the cursor is on a field with the Available value under
assigned time slot Ntt, pressing the spacebar causes this fields values to
cycle through all valid DSX-1 time slots, starting with Ds-p/yy, assuming it is
unassigned. If Ds-p/tt is already assigned, the next valid time slot in the order
described above is displayed.