![Q MODELS/IB MODELS/SU1000C](/images/new-backgrounds/38712/3871247x1.webp)
Ice Machine Operation | Section 3 |
Changing Switch Position During Automatic Operation
Q MODELS/IB MODELS/SU1000C
If the toggle switch is moved to OFF prior to the pump dispensing (less than 45 seconds into the cycle) then switched to:
ICE | A normal |
CLEAN | A manual clean cycle begins. |
| (See “Manual Start Operation,” page |
Q1400C
If the toggle switch is moved to OFF prior to the pump dispensing (less than 45 seconds into the cycle) then switched to:
ICE | A normal |
CLEAN | A manual clean cycle begins. |
| (See “Manual Start Operation,” page |
If the toggle switch is moved to OFF after the pump dispenses (more than 45 seconds into the cycle, but before rinse cycles begin) then switched to:
ICE | The “clean” portion of the cycle begins. |
| After completion of the |
| “Clean” and 6 rinse cycles, the counter |
| resets and a normal |
| begins. |
CLEAN | A manual clean cycle begins. |
| (See “Manual Start Operation,” page |
| After completion of the |
| “Clean” and 6 rinse cycles, the counter |
| resets and the ice machine awaits a |
| change in the toggle switch position. |
If the toggle switch is moved to OFF after the 6 rinse cycles have begun and then switched from off to:
ICE | The rinse portion of the cycle restarts and |
| continues. |
| After completion of the 6 additional rinse |
| cycles, the counter resets and a normal |
| |
CLEAN | A manual clean cycle begins. |
| (See “Manual Start Operation”.) |
| After completion of the |
| “Clean” and 6 rinse cycles, the counter |
| resets and the ice machine awaits a |
| change in the toggle switch position. |
If the toggle switch is moved to OFF after the pump dispenses (more than 45 seconds into the cycle, but before rinse cycles begin) then switched to:
ICE | The ice machine runs 6 rinse cycles, resets |
| the counter and starts a normal ice- |
| making mode. |
CLEAN | A manual clean cycle begins. |
| (See “Manual Start Operation”) |
| After completion of the |
| “Clean” and 6 rinse cycles, the counter |
| resets and the ice machine awaits a |
| change in the toggle switch position. |
If the toggle switch is moved to OFF after the 6 rinse cycles have begun and then switched from off to:
ICE | The ice machine runs 6 rinse cycles, resets |
| the counter and starts a normal ice- |
| making mode. |
CLEAN | A manual clean cycle begins. |
| (See “Manual Start Operation”.) |
| After completion of the |
| “Clean” and 6 rinse cycles, the counter |
| resets and the ice machine awaits a |
| change in the toggle switch position. |
Important
After solution is dispensed (cleaner or sanitizer), the Q1400C ice machine must run 6 rinse cycles. Changing toggle switch position, disconnecting power, etc will not override the 6 rinse cycles. Each time the toggle switch is moved from Off to Ice (or power is interrupted), the six rinse cycles begin again.