Installation Instructions | Section 2 |
Determine Type Of Solution Needed
CAUTION
Use only
The AuCS→A accessory will dispense Cleaner OR Sanitizer. It cannot dispense both at the same time.
CAUTION
Do not mix Cleaner and Sanitizer solutions together. It is a violation of Federal law to use these products in a manner inconsistent with their labeling.
MANITOWOC ICE MACHINE CLEANER Part Number 94-0546-3
Ice Machine Cleaner is used to control
It is recommended for use in places that have lime scale or other mineral deposits built up, but no problems with slime.
MANITOWOC ICE MACHINE SANITIZER Part Number 94-0565-3
Ice Machine Sanitizer is used for sanitizing and controlling algae
It is recommended for use in places such as pizzerias, bars, bakeries, etc., that have airborne bacteria (yeast). Sanitizing is also recommended in places that do not have lime scale (or other mineral deposit problems).
Model | Amount of Cleaner or | |
Sanitizer Dispensed | ||
| ||
Q200 Q280 Q320 Q370 Q420 |
| |
Q450 Q600 Q600C IB600C | *2.4 ounces (70 ml) | |
Q800 Q800C IB800C Q1000 |
| |
Q1000C IB1000C SU1000C |
| |
Q1400C |
| |
Q1300 Q1600 Q1800 QDUAL | *4.8 ounces (140 ml) |
*The dispense rate is automatically controlled
Installing Bottle Of Solution
WARNING
Wear rubber gloves and safety goggles (and/or face shield) when handling Cleaner or Sanitizer.
CAUTION
Follow instructions listed under “Changing Solution Type” on the next page when changing from Cleaner to Sanitizer or from Sanitizer to Cleaner.
1.Place the bottle into the AuCS→A accessory.
2.Slide the tube to the bottom of the bottle and
TUBE MUST BE CLOSE
TO BOTTLE BOTTOM
SV1645
Bottle Installation
WARNING
Do not use 1 gallon bottles of Cleaner or Sanitizer on the AuCS→A