Installation Instructions | Section 2 |
Connection to Ice Machine (cont.)
COMMUNICATION WIRE CONNECTION
Insert the low voltage communication wire through the ½” conduit connecting the AuCS→A to the ice machine.
Plug into the jacks on the ice machine control board and the AuCS→A control board. (Refer to drawing for routing communication wire in ice machine.)
CONTROL BOARD
COMMUNICATION
WIRE
GROUND WIRE
(Q1300/Q1800 ONLY)
ROUTE WIRING
THROUGH
ACCESS HOLES
AS SHOWN
COMMUNICATION
WIRE
30 AND 48 INCH | 22 INCH |
SV1642G
Low Voltage Communication Wire Connection
QDUAL ONLY: The communication wire is attached to the rear of the ice machine control box. The communication wire included with the AuCS→A is not used.
AUCS CONTROL
BOARD
COMMUNICATION
PORT
QDUAL
COMMUNICATION
PORT