Section 2 | Installation Instructions |
Changing Solution Type
CAUTION
Do not mix Cleaner and Sanitizer solutions together. It is a violation of Federal law to use these products in a manner inconsistent with their labeling.
Use the following procedure to flush the system prior to changing from Cleaner to Sanitizer or from Sanitizer to Cleaner.
1.Remove the bottle of Cleaner or Sanitizer from the AuCS→A. Insert a 16 oz. bottle of water.
2.Repeat the following until the water bottle is empty (approximately 8 times):
A.Move the ice machine toggle switch to
CLEAN.
B.The water pump and dump valve will turn on. The dump valve will shut off after approximately 45 seconds.
C.The pump will run for 60 seconds and then dispense for 10 seconds. (The Q1300, Q1600, Q1800 and QDUAL will dispense for
20 seconds).
D.Move the switch to OFF after step C is completed.
3.Install a new bottle of either Cleaner or Sanitizer solution. Refer to “Installing Bottle of Solution” on previous page.
Hose Priming
The dispenser pump requires priming only upon initial installation, or if the hose between the AuCS→A and the ice machine has been pumped dry.
WARNING
Do not blow into or suck on the hose in an attempt to prime it.
CAUTION
Do not prime the hose until installation is complete.
Repeat the following procedure three times:
1.Move the ice machine toggle switch to CLEAN.
2.The water pump and dump valve will turn on. The dump valve will shut off after approximately 45 seconds.
3.The control waits until the water pump runs for
60 seconds, then energizes the AuCS→A pump for 10 seconds. (The Q1300, Q1600, Q1800, and QDUAL will energize for 20 seconds).
4.Allow the ice machine to complete the cleaning or sanitizing cycle.
Refer to Manual Start Operation for details.
Important
The priming procedure starts the automatic cleaning mode. Upon moving the ice machine toggle switch to ICE, the ice machine will run through 6 rinse cycles before making ice.