Setting Frequency Of Cleanings

Installation Instructions

Section 2

Setting Frequency Of Cleanings

The AuCSA is factory-set to clean (or sanitize) the ice machine approximately once every two weeks. For less frequent cleaning, set the selector switch as indicated below. (Refer to “Component Location and Identification” for selector switch location.)

Switch

Time Between

Position

Cleanings

0

No cleaning (OFF)

1

Approximately 2 weeks

(1120 harvests)

 

2

Approximately 4 weeks

(2240 harvests)

 

3

Approximately 12 weeks

(6720 harvests)

 

NOTE: Switch positions 4-9 are inoperative. Do not use them.

Important

Using the AuCSA accessory is supplemental to regular cleaning and sanitizing (per Manitowoc recommendations and local regulations).

Removal From Service/Winterization

Removal From Service/Winterization CAUTION

Leaving solutions in the AuCSA in freezing temperatures may result in severe damage to the dispensing pump. A failure of this nature is not covered by the warranty.

If the AuCSA is to be removed from service for extended periods, or if it is to be exposed to ambient temperatures of 32°F (0°C) or below, follow this procedure:

1.Remove the Cleaning or Sanitizing solution bottle.

2.Follow the instructions under “Hose Priming” to pump all of the solution out of the dispensing pump and line.