Manitowoc Ice QF0800, QC0700 Water Level Probe Removal, QF2300 Water Reservoir Cover Removal

Models: QF0400 QC0700 QF0800 QF2300

1 60
Download 60 pages 62.23 Kb
Page 44
Image 44

Ice Machine Operation

Section 3

 

 

Water Level Probe Removal

QF400/QC700/QF800/QF2300

Water Level Probe Removal

1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.

2.Disconnect water supply line at float valve quick disconnect by depressing stainless steel lever.

3.Pull up on water level probes to remove.

4.Disconnect wires from water level probes or control board.

WATER LEVEL

PROBES

SV2043

QF400

WATER LEVEL

PROBES

SV2028

QC700/QF800

WATER LEVEL

PROBES

SV1791

QF2300

Water Reservoir Cover Removal

1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.

2.Remove water level probes.

3.Remove water float valve coil.

4.Depress coil and rotate 1/4 turn counterclockwise.

5.With coil wires attached, lift coil off enclosure tube.

6.QF0800/QC0700 ONLY Rotate quarter turn fasteners counterclockwise.

7.QF0800/QC0700 ONLY Remove cotter key and pin from ice chute.

8.Remove top cover from float reservoir.

4

5

3

6

SV2030

QC700/QF800 Shown

3-12

Part Number 000002688

Page 44
Image 44
Manitowoc Ice QF0800, QC0700, QF0400 Water Level Probe Removal, QF2300 Water Reservoir Cover Removal, QC700/QF800 Shown