Manitowoc Ice QF0400, QF2300, QF0800 manual Section Installation Instructions Installation Checklist

Models: QF0400 QC0700 QF0800 QF2300

1 60
Download 60 pages 62.23 Kb
Page 31
Image 31

Section 2

Installation Instructions

 

 

Installation Checklist

Is the Ice Machine level?

Has all of the internal packing been removed?

Have all of the electrical and water connections been made?

Has the supply voltage been tested and checked against the rating on the nameplate?

Is there proper clearance around the ice machine for air circulation?

Has the ice machine been installed where ambient temperatures will remain in the range of 45° - 110°F (7° - 43.3°C)?

Has the ice machine been installed where the incoming water temperature will remain in the range of 45° - 90°F (7° - 32.2°C)?

Are the ice machine and bin drains separately vented?

Are all electrical leads free from contact with refrigeration lines and moving equipment?

Has the owner/operator been instructed regarding maintenance and the use of Manitowoc Cleaner and Sanitizer?

Has the warranty registration card been sent to the factory?

Has the ice machine and bin been sanitized?

Has this manual been given to the owner/ operator?

Is the water level (float valve) set correctly?

Has the toggle switch been placed in the ice position? (Switch is located behind front cover)

REMOTE AIR-COOLED ONLY

Has the ice machine receiver service valve been opened 100%?

Are the ice machine line set shut-off valves open 100%?

Does the condenser fan motor operate properly after start-up?

Have all the refrigeration fittings and joints been leak checked?

Is the line set routed properly?

Is a refrigeration oil trap (S-trap) installed?

Have the refrigeration lines been insulated and secured properly to prevent vibration?

Has the remote condensing unit been located where ambient temperatures will remain in the range of -20° to 120°F (-29° to 49°C)?

Is the lineset length, rise and drop within guidelines?

Part Number 000002688

2-21

Page 31
Image 31
Manitowoc Ice QF0400, QF2300, QF0800 manual Section Installation Instructions Installation Checklist, Remote AIR-COOLED only