Before Calling Service
Checklist
If a problem arises during operation of your ice machine, follow the checklist below before calling for service. Routine adjustments and maintenance procedures are not covered by the warranty.
Problem | Possible Cause | To Correct |
Ice machine does not operate. | No electrical power to the ice machine. | Replace the fuse/reset the breaker/turn on |
|
| main power switch/plug cord into receptacle. |
| Control Board fuse open | |
| ICE/OFF/CLEAN toggle switch set improperly. | Move toggle switch to the ICE position. |
| 8 minute lockout has not expired. | Bin level light will flash to indicate 8 minute |
|
| lockout has not expired. Refer to Sequence of |
|
| Operation |
| Bin level sensor is disconnected or is | Connect bin level sensor or remove ice |
| contacting the ice. | contacting probe. |
| High Pressure Control is open. | Clean condenser, check fan motor, check high |
|
| pressure control operation. |
Gear Motor runs but | Water reservoir is empty. (Water must contact | Open water service valve or clean float valve |
compressor will not start. | the water level probe to start the compressor). | screen. |
| Water level probes out of position | Correct water level probe position. |
Remotes Only | No electrical power to condensing unit | Replace the fuse/reset the breaker/turn on the |
|
| main power switch. |
Ice machine stops and can be | The SafeGuard feature is stopping the ice | Refer to “SafeGuard Feature” in this section |
restarted by moving the toggle | machine. |
|
switch to OFF and back to ICE. |
|
|
Ice quality is poor. | Poor incoming water quality. | Contact a qualified service company to test the |
|
| quality of the incoming water and check filter. |
| Water filtration is poor. | Replace filter. |
| Incoming water temperature is above 90°F | Correct water temperature. (Verify check/ |
| (32.3°C) | mixing valves in other equipment are working |
|
| properly). Connect the ice machine to a cold |
|
| water supply. |
| Water pressure is low. | Water pressure must remain between 20 and |
|
| 80 psig. |
| Water softener is working improperly (if | Repair the water softener. |
| applicable). |
|
Low ice capacity. | Water float valve screen is dirty. | Remove and clean the filter screen. |
| Incoming water supply is | Open the water service valve. |
| Water dump valve is leaking. | Clean the dump valve. |
| Water Pressure is low. | Water pressure must remain between 20 and |
|
| 80 psig. |
| Incoming water temperature is above 90°F | Correct water temperature. (verify check/ |
| (32.2°C) | mixing valves in other equipment is working |
|
| properly) |
| Water float valve stuck open or leaking. | Remove the float valve and clean it. |
Objects stacked around ice machine, blocking | Remove items blocking airflow. | |
| airflow to condenser. |
|
| High air temperature around ice machine. | Air temperature must not exceed 110°F |
|
| (43.3°C) |
| Inadequate clearance around the ice machine. | Provide adequate clearance. |
| The condenser is dirty. | Clean the condenser. |