Manitowoc Ice QF2300, QF0800, QC0700, QF0400 manual Condenser Air Baffle, Leveling Leg and Foot

Models: QF0400 QC0700 QF0800 QF2300

1 60
Download 60 pages 62.23 Kb
Page 16
Image 16

Installation Instructions

Section 2

 

 

Leveling the Ice Storage Bin

1.Screw the leveling legs onto the bottom of the bin.

2.Screw the foot of each leg in as far as possible.

!Caution

The legs must be screwed in tightly to prevent them from bending.

3.Move the bin into its final position.

4.Level the bin to assure that the bin door closes and seals properly. Use a level on top of the bin. Turn each foot as necessary to level the bin.

5.Inspect bin gasket prior to ice machine installation. (Manitowoc bins come with closed cell foam gasket installed along the top surface of the bin.)

6.Install ice machine on bin.

NOTE: An optional caster assembly is available for use in place of the legs. Installation instructions are supplied with the casters.

THREAD LEVELING

LEG INTO BASE OF

CABINET

THREAD ‘FOOT’ IN AS

FAR AS POSSIBLE

SV1606

Leveling Leg and Foot

Condenser Air Baffle

(QC700/QF800 Air-Cooled Ice Machines Only)

The air-cooled baffle prevents condenser air from recirculating. To install:

1.Remove the back panel screws next to the condenser.

2.Align the mounting holes in the air baffle with the screw holes and reinstall the screws.

AIR

BAFFLE

SCREWS

SV1607

Air Baffle

2-6

Part Number 000002688

Page 16
Image 16
Manitowoc Ice QF2300, QF0800, QC0700 Condenser Air Baffle, Leveling Leg and Foot, QC700/QF800 Air-Cooled Ice Machines Only