Section 2 | Installation Instructions |
|
|
Refrigeration System Installation
(QF2300/RFC2385 ONLY)
QuietQube® |
| Remote Single |
|
| |||
| Circuit |
| Line Set* | ||||
Ice Machine |
|
| |||||
| Condenser |
|
| ||||
|
|
|
|
| |||
|
|
|
|
|
| ||
RFC2300 |
|
| RFC2385 |
| |||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
Line Set | Suction Line | Liquid Line | Insulation | ||||
Thickness | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
| 1/2” (13mm) | |
RC 20/30/50 |
| 3/4 inch | 1/2 inch | Suction Line | |||
| (19.1 mm) | (12.7 mm) | 1/4” (7mm) | ||||
|
| ||||||
|
|
|
|
|
| Liquid Line |
USAGE WITH NON-MANITOWOC
CONDENSING UNITS
Manitowoc Condensing Units are specifically designed for usage with a Manitowoc Flake/Chiplet Ice Machine Head Sections. Manitowoc Flake/Chiplet Ice Machines will not operate with
!Warning
Installation of a Remote Condensing Unit may require the use of special equipment for placement. Trained and qualified personnel are required for proper rigging and lifting.
!Caution
The
Factory Equipment Refrigeration Amounts
ICE MACHINE HEAD SECTION
Each ice machine head section ships from the factory with a
Series | Charge |
QF2200/QF2300 | 0’ to 50’ linesets 12.5 lbs (5.7 kg) |
RFC2085/ | 50’ to 100’ linesets 14.0 lbs (6.4 kg) |
RFC2385 |
|
!Caution
Never add more than nameplate charge to the refrigeration system for any application.
!Warning
Potential Personal Injury Situation
The ice machine head section contains the refrigerant charge. Installation and brazing of the line sets must be performed by a properly trained and EPA certified refrigeration technician aware of the dangers of dealing with refrigerant charged equipment.
REMOTE CONDENSING UNIT
Each condensing unit ships from the factory pressurized with 50/50 nitrogen helium mixture that must be removed during the installation process (approximately 20 psig).
REFRIGERATION LINE SETS/TRAPS KIT
Refrigeration Rated Tubing and Trap Kits are shipped capped with atmospheric pressure.
Part Number 000002688 |