Ice Machine Operation

Section 3

 

 

Water Reservoir Removal

1.Place the toggle switch in the OFF position and turn off the water supply to the ice machine at the water service valve.

2.Disconnect water supply line at float valve quick disconnect by depressing stainless steel lever.

3.Place the toggle switch in the ICE position. The dump valve will open and the float reservoir will empty.

4.After the reservoir is empty, place the toggle switch in the OFF position and disconnect power to the ice machine at the service disconnect.

5.Remove water float valve coil.

A.Depress coil and rotate 1/4 turn counterclockwise.

B.With coil wires attached, lift coil off enclosure tube.

5.QF0800/QC0700 ONLY Rotate quarter turn fasteners counterclockwise.

6.QF0800/QC0700 ONLY Remove cotter key and pin from ice chute.

7.Remove top cover from float reservoir.

8.Lift float valve out of float reservoir.

9.Disconnect the drain lines from reservoir.

10.Lift reservoir off of evaporator assembly.

WATER

RESERVOIR

EVAPORATOR

ASSEMBLY

SV2024

QC700/QF800 Shown

Ice Diverter Removal

QF0400

1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.

2.Remove thumbscrews and lift panel forward.

3.Remove bin level sensor from white plastic panel.

4.Remove ice diverter from bin.

5.When the bin level sensor is reinstalled the correct position is 4.5” (114 mm) from the left edge of the white panel.

2

3

LOCATE BIN LEVEL SENSOR 4.5”

FROM EDGE OF WHITE PANEL

SV2052

3-14

Part Number 000002688

Page 46
Image 46
Manitowoc Ice QC0700, QF2300, QF0800, QF0400 manual Water Reservoir Removal, QC700/QF800 Shown Ice Diverter Removal