Section 3

Ice Machine Operation

 

 

Water Reservoir Cover Removal

QF2300

1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.

2.Remove water level probes.

3.Remove water float valve coil.

4.Depress coil and rotate 1/4 turn counterclockwise.

5.With coil wires attached, lift coil off enclosure tube.

6.Remove top cover from float reservoir.

3, 4, 5

2

6

SV1791

QF2300 Shown

Float Valve Removal

1.Place the toggle switch in the OFF position, turn off the water supply and disconnect electrical power to the ice machine.

2.Disconnect water supply line at float valve quick disconnect by depressing stainless steel lever.

3.Remove water float valve coil.

4.Depress coil and rotate 1/4 turn counterclockwise.

5.With coil wires attached, lift coil off enclosure tube.

6.QF0800/QC0700/QF2300 ONLY Rotate quarter turn fasteners counterclockwise.

7.QF0800/QC0700 ONLY Remove cotter key and pin from ice chute.

8.Remove top cover from float reservoir.

9.Lift float valve out of float reservoir.

FLOAT VALVE

SV2015

QC700/QF800 Shown

Part Number 000002688

3-13

Page 45
Image 45
Manitowoc Ice QF0800, QC0700, QF0400 manual QF2300 Shown Float Valve Removal