Testing Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor before servicing, unless testing requires power.
RLY 3
2 1
TAB 1
TAB 2
| 9 8 | 5 4 3 | 1 |
| |
| CN1 |
|
|
|
|
|
|
|
|
|
|
Function | Test | Meter |
| Probe Placement | Results |
| Condition | Setting |
|
|
|
Power to current | All Conditions | Volts |
| Tab 1 to CN1 Pin 3 (Neutral) | 120 VAC |
transformer |
|
|
|
|
|
Power from current | All Conditions | Volts |
| Tab 2 to CN1 Pin 3 (Neutral) | 120 VAC |
transformer |
|
|
|
|
|
|
|
|
|
|
|
Power from Oven TCO | All Conditions | Volts |
| CN1 – Pin 1 (Black wire to Neutral) | 120 VAC |
Power to Oven Light | Standby | Volts |
| CN1 – Pin 4 to Pin 1 | 120 VAC |
| Ready | Volts |
| CN1 – Pin 4 to Pin 1 | 0 VAC |
| Cook | Volts |
| CN1 – Pin 4 to Pin 1 | 0 VAC |
Power to Blower Motor | Standby | Volts |
| CN1 – Pin 5 to Pin 1 | 120 VAC |
| Ready | Volts |
| CN1 – Pin 5 to Pin 1 | 0 VAC |
| Cook | Volts |
| CN1 – Pin 5 to Pin 1 | 0 VAC |
Secondary Interlock | Door Closed | Ohms |
| CN1 – Pin 8 to Pin 9 | Continuity |
Switch | Door Opened .... | Ohms |
| CN1 – Pin 8 to Pin 9 | Infinite |
|
|
|
|
|
|
Power to Relay 3 | Standby | Volts |
| Relay 3 – Pin 1 to Pin 2 | 120 VAC |
| Ready | Volts |
| Relay 3 – Pin 1 to Pin 2 | 120 VAC |
| Cook | Volts |
| Relay 3 – Pin 1 to Pin 2 | 0 VAC |
©2004 Maytag Services | 16023293 Rev. 0 | 23 |