Maytag RCS10DA, RFS Magnetron Thermal Cut-Out TCO, Cavity Thermal Fuse, Oven Light Removal

Models: RFS RCS RCS10DA

1 36
Download 36 pages 32.79 Kb
Page 31
Image 31
Magnetron Thermal Cut-Out (TCO)

Disassembly Procedures

!WARNING

To avoid the risk of electrical shock, personal injury, or death, disconnect power to oven and discharge the capacitors before following any disassembly procedure.

Magnetron Thermal Cut-Out (TCO)

1.Disconnect power to oven and remove outer case, (see "Outer Case" procedure).

2.Remove outer case.

3.Remove TCO by removing screws.

4.Disconnect wiring.

5.Replace component and reverse procedure to reassemble.

NOTE: When reconnecting wiring to thermal fuses the connectors must be tight.

Cavity Thermal Fuse

1.Disconnect power to oven and remove outer case, (see "Outer Case" procedure).

2.Remove outer case.

3.Remove thermal fuse mounting screw.

4.Disconnect wiring.

5.Replace component and reverse procedure to reassemble.

NOTE: When reconnecting wiring to thermal fuses the connectors must be tight.

Oven Light Removal

The light bulb for inside of the oven can be changed only from the side of the unit. On the left hand side of the oven is a metal plate with one screw. The light bulb is located behind this plate.

Follow these steps to change the bulb:

1.Disconnect power to oven and remove outer case, (see "Outer Case" procedure).

2.Remove screw and plate from side of unit.

3.To remove bulb, turn it counterclockwise, being careful not to burn fingers or break the bulb.

4.Replace bulb with a 40 watt, 115 - 125 volt appliance bulb.

5.Reposition plate, being careful not to bend hinge tab. Replace and tighten screw. Do not operate oven without plate in place.

Tray Replacement

1.Unplug oven from outlet.

2.Using a suction cup to pry upward on front portion and remove tray from unit.

3.Thoroughly clean and degrease sump area.

4.Clean oven cavity bottom where new oven tray will make contact using mineral spirits or any non-flammable degreasing solvent.

NOTE: Detergents, soap, and water are not sufficient to remove oil and grease.

5.Place new tray into unit and clean cavity with mild detergent to remove any remaining degreasing solvant.

©2004 Maytag Services

16023293 Rev. 0

31

Page 31
Image 31
Maytag RCS10DA, RFS manual Magnetron Thermal Cut-Out TCO, Cavity Thermal Fuse, Oven Light Removal, Tray Replacement