Maytag RCS10DA, RFS manual Troubleshooting Procedures, Condition, Check, Result, Cause, Remedy

Models: RFS RCS RCS10DA

1 36
Download 36 pages 32.79 Kb
Page 12
Image 12
Condition

Troubleshooting Procedures

Trouble 1: The following visual conditions indicate a probable failed control circuit.

1.Incomplete segments.

Segment missing.

Partial segment missing.

Digit flickering (Note: Slight flickering is normal.)

2.Colon does not turn on or blink.

3.A distinct change in the brightness of one or more numbers in display.

4.One or more digits in the display are not lighting.

5.Display indicates a number different from one touched, for example, key in 5 and 3 appears in the display.

6.Specific numbers (for example 7 or 9) will not display when key pad is touched.

7.Display does not count down with time blinking or up with clock operation.

8.Display obviously jumps in time while counting down.

9.Display counts down too fast while cooking.

10.Each indicator light does not turn on after setting cooking cycle. 11. Display time of day does not reappear when cooking is finished.

Condition

Check

Result

Cause

 

Remedy

No input can be

Check the connection

Continuity

Failed

 

Replace

programmed.

between keypad and

No continuity

controller.

 

controller.

 

controller.

 

Loose

 

Repair

 

 

 

connection.

 

connection.

1. Some inputs

Replace keypad and check

Everything

Failed

 

Replace

cannot be

operation.

works as

keypad.

 

keypad.

programmed.

 

specified.

 

 

 

2.Display shows a number or figure different

from one

Still have

Failed

Replace

touched.

trouble.

controller.

controller.

3.Random programming when touching other pads.

4.Display is fixed at some figure and can not accept any input.

12

16023293 Rev. 0

©2004 Maytag Services

Page 12
Image 12
Maytag RCS10DA, RFS manual Troubleshooting Procedures, Condition, Check, Result, Cause, Remedy