Disassembly Procedures
To avoid the risk of electrical shock, personal injury, or death,
!WARNING disconnect power to oven and discharge the capacitors before following any disassembly procedure.
Door Assembly | Door Disassembly |
!CAUTION
A microwave leakage test must be performed anytime a door assembly is removed, replaced, disassembled, or adjusted for any reason.
Door Removal
1.Disconnect power to oven.
2.Open oven door, remove top hinge cap, and slowly lift door to disengage the hinge pins at top and bottom.
Top hinge cap |
3.To reinstall door, place top pin into slot first, then align bottom pin.
4.Reinstall top hinge cap.
1.Disconnect power to oven.
2.Remove oven door, (see "Door Removal").
3.Begin at the bottom of the door near hinge, insert flat blade screwdriver between choke cover and outer door panel. Gently pry upward on choke cover to release tabs. Work in clockwise direction to remove choke cover.
!CAUTION
To avoid property damage, care must be taken when prying choke cover from oven door.
4.Remove screw securing door handle to latch assembly.
5.Slide latch assembly downward and pull away from door frame to release.
6.Remove screws securing choke assembly to outer door panel.
NOTE: When disassembling door, use caution to prevent deformation of slats on door frame/choke assembly.
7.Begin at hinge side of door near bottom, insert flat blade screwdriver between door frame/choke assembly and outer door panel. Gently pry outer door panel away from door frame to release tabs. Work in clockwise direction to remove door frame.
8.Remove spring from hinge assembly.
9.Remove screws securing hinge assembly to choke assembly.
10.Reassemble in reverse order.
| Choke | Top |
| cover | |
| hinge | |
|
| |
|
| cap |
Outer |
|
|
Door |
|
|
panel |
|
|
|
| Latch |
|
| assembly |
Door |
| Spring |
| Door frame/ | |
Handle |
| |
| choke assembly | |
|
| |
* Tighten side screw first and apply Loctite |
26 | 16023293 Rev. 0 | ©2004 Maytag Services |