Blower Motor or Wheel

Disassembly Procedures

To avoid the risk of electrical shock, personal injury, or death,

!WARNING disconnect power to oven and discharge the capacitors before following any disassembly procedure.

Blower Motor or Wheel

Splatter Shield

1.Disconnect power to oven and remove outer case, (see "Outer Case" procedure).

2.Remove outer case.

3.Disconnect wiring from blower motor.

4.Remove screws securing scroll to chassis.

5.Slide scroll discharge snout from partition and lift scroll assembly from unit.

6.Replace component and reverse procedure to reassemble.

NOTE: Be careful not to bend antenna when removing splatter shield. Shield snaps into a lip in front of the oven and three slots in the back.

1.Place your thumbs in the two indentations in front of the shield.

2.Press lightly towards the back and carefully lower shield away from antenna.

3.Pull shield out of the back slots and out of the oven.

Splatter

shield

Antenna

1.Remove splatter shield from oven cavity.

2.Remove two mounting rivets on the top of oven cavity to remove cradle. Support cradle before removing mounting rivets to avoid damage to antenna assembly.

Stirrer Motor

1.Disconnect power to oven and remove outer case, (see "Outer Case" procedure).

2.Remove outer case.

3.Disconnect wire terminal s from stirrer motor.

4.Remove screws securing stirrer motor to wave guide.

5.Replace component and and reverse procedure to reassemble.

NOTE: When replacing stirrer motor, verify motor shaft is aligned with antenna shaft before securing with screws.