Disassembly Procedures
To avoid the risk of electrical shock, personal injury, or death,
!WARNING disconnect power to oven and discharge the capacitors before following any disassembly procedure.
! CAUTION | Interlock Switches |
| |
Primary switch is operated by bottom latch arm. | |||
A microwave leakage test must be performed anytime | Interlock Switch Removal |
| |
a door assembly is removed, replaced, disassembly, or |
| ||
1. Disconnect power to oven and remove outer case, | |||
adjusted for any reason. | |||
(see "Outer Case" procedure). |
| ||
|
| ||
| 2. Remove control panel, (see "Control Panel" section). | ||
| 3. Test interlock switches before removing, (see testing | ||
Control Panel Removal | procedures). |
| |
4. Disconnect and label wire connections. | |||
1. Disconnect power to oven and remove outer case, | |||
5. Remove mounting screws securing interlock switch to | |||
(see "Outer Case" procedure). | |||
unit chassis. |
| ||
2. Disconnect and label wires from controller/timer. |
| ||
6. Remove switches by carefully releasing locking tabs | |||
3. Open oven door. | |||
on switch bracket and tilting switches to remove from | |||
4. Remove screw securing top of control panel to cavity. | |||
switch bracket. |
| ||
Lift control panel up and out to release tabs. |
| ||
| Tab | ||
|
| ||
| Monitor | NC | |
| COM | ||
| Switch | ||
|
| NO | |
| Primary |
| |
| Switch | COM | |
|
| ||
| Secondary | NO | |
| Switch | ||
|
| ||
|
| COM | |
|
| Tab |
5.Replace component and reverse procedure to reassemble.
NOTE: After repairing the door or the interlock system, it is necessary to check the switch continuity before operating the oven.
!CAUTION
Before replacing a blown monitor fuse, test the primary interlock switch, secondary interlock switch, monitor switch, and power relay contacts for proper operation. If the monitor fuse is blown by a failed switch operation, all switches and controller must be