Maytag UMV1152CA manual Error Code Table, Troubleshooting Procedures, 16027303

Models: UMV1152CA

1 80
Download 80 pages 57.87 Kb
Page 12
Image 12
Error Code Table

Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to microwave oven and discharge the high-voltage capacitor before servicing, unless testing requires power.

Error Code Table

Error Code

Explanation

Possible Cause

SE

Keypad shorted 10 seconds or longer.

Sticky keypad(s).

 

 

 

E03

Convection motor or convection heater open.

Motor and/or heater unplugged, wiring or PCB

 

 

assembly.

E11

Gas sensor open error.

Sensor unplugged, wiring or PCB assembly.

E12

Gas sensor short error.

Sensor unplugged, wiring or PCB assembly.

 

 

 

E13

T1 Max time error (oven did not preheat properly).

PCB assembly.

 

 

 

E21

Thermal sensor open error.

Sensor unplugged, wiring or PCB assembly.

 

 

 

E22

Thermal sensor short error.

Sensor unplugged, wiring or PCB assembly.

E23

PREHEAT did not reach preset temperature within 30

Convection heater or grill heater unplugged, wiring

minutes. Preheat cycle canceled.

or PCB assembly.

 

E24

Microwave temperature reaches 500° F (260° C) in

Thermal or gas sensor, wiring or PCB assembly.

 

overheat condition. Microwave cancels all functions.

 

E61

Sensor open error.

Sensor unplugged, wiring or PCB assembly.

E62

Sensor shorted error.

Sensor shorted or PCB assembly.

E63

T1 Max Time error.

PCB assembly.

 

 

 

12

16027303

© 2006 Maytag Services

Page 12
Image 12
Maytag UMV1152CA manual Error Code Table, Troubleshooting Procedures, 16027303