Maytag UMV1152CA Testing Procedures, 16027303, Illustration, Component, Test Procedure, Results

Models: UMV1152CA

1 80
Download 80 pages 57.87 Kb
Page 15
Image 15
Manual background

Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to microwave oven and discharge the high voltage capacitor before servicing, unless testing requires power.

Illustration

Component

Test Procedure

Results

 

Convection heater element

Remove all wires from heater.

 

 

JMV9169BA*,

Measure resistance across terminals

Approx. 15-25 Ω (70° F, 20° C).

 

JMV8166BA*,

 

 

 

AMV6167BD*

 

 

 

Convection motor

Remove all wires from motor.

 

 

JMV9169BA*,

Measure resistance across coil

Approx. 14.5 - 17 Ω.

 

JMV8166BA*,

 

 

 

AMV6167BD*

 

 

 

Primary interlock switch test

Measure resistance between

 

 

(Bottom switch)

terminals 1 and 2:

Open (Infinite).

 

1

Door Open

 

Door Closed

Continuity.

 

 

 

2

 

 

 

Secondary interlock switch

Measure resistance between

 

 

test

terminals 1 and 2:

Open (Infinite).

 

(Top switch)

Door Open

 

 

Door Closed

Continuity.

 

 

Interlock monitor switch test

Measure resistance between

 

 

 

(Middle switch)

terminals 1 and 2:

Continuity.

 

 

1

Door Open

 

 

2

Door Closed

Open (Infinite).

 

 

 

 

B A

Fan motor

Remove all wires from motor.

 

C

 

MMV4205BA*, AMV5206BA*,

Measure resistance

Approx. 28 - 35 Ω.

 

 

MMV5207BA, JMV8208B**,

 

 

JMV9169BA*, JMV8166BA*,

 

Infinite or several, motor is defective.

 

 

AMV6167BD*

 

 

 

Stirrer Motor

Measure voltage across terminals

Approx. 120 VAC.

 

 

UMV1152CA*, AMV1154BA*,

Measure resistance across terminals

Approx. 3 to 4 Ω.

 

 

AMV5164BA*, MMV1153BA*,

 

 

 

 

MMV5165BA*

 

 

 

 

Stirrer Motor

Measure voltage across terminals

Approx. 120 VAC.

 

 

 

Measure resistance across terminals

Approx. 108 to 132 kΩ.

 

 

Turntable Motor

Measure voltage across terminals

Approx. 120 VAC.

 

 

UMV1152CA*, AMV1154BA*,

Measure resistance across terminals

Approx. 3 to 4 Ω.

 

 

AMV5164BA*, MMV1153BA*,

 

 

 

 

MMV5165BA*

 

 

 

 

Turntable Motor

Measure voltage across terminals

Approx. 120 VAC.

 

 

 

Measure resistance across terminals

Approx. 108 to 132 kΩ.

 

 

Damper Motor

Measure voltage across terminals

Approx. 120 VAC.

 

 

JMV9169BA*, JMV8166BA*,

Measure resistance across terminals

Approx. 3 to 4 kΩ.

 

 

AMV6167BD*

 

 

 

 

Louvre Motor

Measure voltage across terminals

Approx. 120 VAC.

 

 

JMV8208B**, JMV9169BA*,

Measure resistance across terminals

Approx. 3100 to 3900 kΩ.

 

 

JMV8166BA*, AMV6167BD*

 

 

© 2006 Maytag Services

16027303

15

Page 15
Image 15
Maytag UMV1152CA manual Testing Procedures, 16027303, Illustration, Component, Test Procedure, Results