
  9
CRADLE INSTALLATION TO THE HOST DEVICE 
1.  Turn off the host system. 
2.  Connect the 10-pin RJ45 male 
connector into the 10-pin modular 
jack on the bottom of the cradle.  
3.  Connect the 6-pin Mini-DIN male 
connector of the keyboard cable to 
keyboard port on the host device. 
4.  Plug the external power supply into 
the power jack on the bottom of the 
cradle.  
Check the AC input 
requirements of the power 
supply to make sure the 
voltage matches the AC 
outlet. The outlet must be 
located near the requirement 
and be easily accessible. 
5.  Plug the power supply into the AC 
outlet.  The blue LED on the rear of 
the cradle will stay on. 
6.  Turn on the host device. 
7.  Establish communication between the scanner and cradle.   
See page 15 for complete instructions on Establishing Bluetooth 
Communication between the scanner and cradle. 
The scanner must be charged for a minimum of 3 hours before the 
scanner can be placed in full operation for the first time.  After the initial 
preparation charge of 3 hrs, the battery will only require 2.5 hrs to come 
to a full charge when it gives a Low Power warning (see page 18). 
See page 6. 
Figure 6. Stand Alone Keyboard