 29
TROUBLESHOOTING GUIDE 
The following guide is for reference purposes only.  Contact a Metrologic 
representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited 
warranty terms.  
Symptoms  Possible Causes  Solution 
The scanner  
has no LEDs, 
beeper or laser 
while seated in 
cradle. 
No power is being 
supplied from cradle 
to scanner. 
Check the transformer, outlet and 
power strip.  Verify the power 
cable is plugged into the cradle 
properly. 
The scanner  
has no LEDs, 
beeper or laser 
when out of the 
cradle. 
The scanner’s 
internal battery is not 
supplying power to 
scanner. 
Place the scanner into the cradle 
to recharge the battery.  
The scanner 
locks up after 
the first scan.  
The white LED 
stays on and 
the unit razzes 
twice. 
Communication has 
not been established 
between scanner and 
cradle. 
Establish communication between 
scanner and cradle before 
scanning a normal bar code. 
The scanner 
locks up after 
scanning a bar 
code.  The 
white LED stays 
on and the unit 
razzes twice. 
The distance between 
scanner and cradle is 
beyond the 10-meter 
operation range and 
RangeGate is not 
activated. 
Bring the scanner back into the 
10-meter communication range 
from the cradle.  
The scanner 
emits 2 beeps 
with alternately 
flashing LEDs 
on power-up. 
There may be a 
possible ROM failure.  A flash ROM upgrade required.