34
DESIGN SPECIFICATIONS Scanner and Cradle Specifications
Electrical
Scanner: 5.2VDC ± 0.25V
Input Voltage:
Cradle: 5.0VDC ± 0.25V
Cradle Power: 0.6 W
Operating 1.15 W
Scanner Power: Sleep 150 mW
Operating 230 mA@5VDC
Scanner Current: Sleep 30mA@ 5VDC
Cradle Current: Cradle: 120 mA @ 5VDC
DC Transformers: Class II; 5.0V @ 2A
Battery Capacity
/Recharge Time: 12000 scans per charge / recharge time = 2.5 hours
Radio Range: 10 m (33 ft)
For regulatory compliance information, see pages 47 - 49.
Environmental
Operating = 0°C to 40° (32° to 104°F)
Temperature:
Storage = -20°C to 50°C (-4°F to 122°F)
Humidity: 5% to 95% relative humidity, non-condensing
Light Levels: Up to 4842 Lux (450 footcandles)
Shock: Designed to withstand 1.5 m (5’) drops
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None required
* All specifications are subject to change without notice.