 34 
DESIGN SPECIFICATIONS  Scanner and Cradle Specifications 
Electrical   
Scanner:   5.2VDC  ± 0.25V 
Input Voltage: 
Cradle:   5.0VDC  ± 0.25V 
Cradle Power:  0.6 W 
Operating 1.15 W 
Scanner Power:  Sleep 150 mW 
Operating 230 mA@5VDC 
Scanner Current:  Sleep 30mA@ 5VDC 
Cradle Current:  Cradle: 120 mA @ 5VDC 
DC Transformers:  Class II; 5.0V @ 2A 
Battery Capacity 
/Recharge Time:  12000 scans per charge / recharge time = 2.5 hours 
Radio Range:  10 m (33 ft) 
For regulatory compliance information, see pages 47 - 49. 
Environmental   
Operating = 0°C to 40° (32° to 104°F) 
Temperature: 
Storage = -20°C to 50°C (-4°F to 122°F) 
Humidity:  5% to 95% relative humidity, non-condensing 
Light Levels:  Up to 4842 Lux (450 footcandles) 
Shock:  Designed to withstand 1.5 m (5’) drops 
Contaminants:  Sealed to resist airborne particulate contaminants 
Ventilation: None required 
* All specifications are subject to change without notice.