WARNING:
WARNING: IF FOR ANY REASON THE EMERGENCY STOP MECHANISM DOES NOT FUNCTION PROPERLY, DO NOT USE THE MACHINE UNTIL IT IS REPAIRED. FAILURE TO HEED MAY RESULT IN SERIOUS PERSONAL IN-
OPERATION OF THE EMERGENCY STOP
JURY OR DEATH.
RESETTING THE EMERGENCY STOP
Across the upper edge of the front unloading unit is a “Warning Push For Emergency Stop” pushbar. By pushing on this bar during front unloading operation only, the forage box will shut down in an emergency.
Emergency stop trip cables connected to the “Emer- gency Stop” pushbar extend along both sides and down the front of the forage box. Pulling on these trip cables will also shut down the front unloading unit of the forage box in an emergency.
Note: The emergency stop mechanism DOES NOT STOP the PTO drive shaft, nor the rear unloading op- eration of the forage box.
WARNING: THE EMERGENCY STOP MECHA- NISM STOPS ONLY THE FRONT UNLOADING UNIT FROM OPERATING AND NOT THE REAR UNLOADING OPERATION OF THE FORAGE BOX!
EMERGENCY STOP TRIP LOCATIONS
EMERGENCY STOP
PUSH BAR
WARNING: DO NOT RESET THE EMER- GENCY STOP MECHANISM UNTIL ALL PEOPLE, TOOLS AND OTHER OBJECTS ARE WELL CLEAR OF THE FORAGE BOX. FAILURE TO HEED MAY RE- SULT IN SERIOUS PERSONAL INJURY OR DEATH.
INDEPENDENT OUTFEED CLUTCH CONTROL
LEVER
To reset the emergency stop mechanism, fully en- gage the INDEPENDENT OUTFEED CLUTCH con- trol lever into the “RUN” position.
Check frequently to be assured that the emergency stop mechanism is in proper operating condition. Slowly engage the tractor PTO and operate the for- age box at an idle speed to ensure it is operating properly. Push the emergency stop bar across the upper edge of the front unloading unit, to ensure that the forage box can be shut down in an emergency.
Reset the emergency stop and recheck using the emergency stop trip cables at various locations to en- sure that the forage box can be shut down in an emer- gency. Periodically repeat emergency stop inspections during the operating season and at all times keep excessive slack out of the emergency stop trip cables.
EMERGENCY STOP TRIP | EMERGENCY STOP |
CABLES EXTENDING | TRIP CABLE AT |
ALONG BOTH SIDES | FRONT |
3200 & 4200 Series |