Coupling seal

Cleaning and care

Coupling seal

The coupling seal needs to be lubricated regularly. If the water container becomes difficult to remove and replace or the fault message F20 appears, rub a small amount of the silicone grease supplied (see "Accessories supplied") into the inside of the coupling seal. When doing this, do not detach the seal but leave it in place.

When handling silicone grease, please observe the following safety measures:

Remove any silicone grease from your skin either by wiping it off or by washing it off.

If the grease gets into the eyes it must be rinsed out with plenty of clean water.

If it is swallowed, seek medical advice.

The coupling seal should be replaced with a new one if it becomes brittle or porous over time or if an unusually large amount of water collects on the floor of the water container compartment.

Coupling seals can be ordered from the Miele Spare Parts Department. See back page for contact details.

Only use the silicone grease supplied. On no account must margarine or oil or any other domestic grease or fat be used, as these can cause the seal to swell.