Maintenance
Cleaning the spray arms
Waste particles can lodge in the spray arm jets.
It is therefore important to inspect the spray arms regularly.
Use a sharp pointed object to push particles into the spray arm jets, and rinse well under running water.
Remove the spray arms as follows:
Take any mobile units out of the wash cabinet.
Spray arms in the wash cabinet:
Loosen the securing clip on the spray arm connection and then pull the spray arm upwards or downwards.
Remove the seal and the bearing and clean them.
Refit the bearing and the seal.
Spray arms in mobile units/modules:
Turn the nut (left hand thread) together with the spray arm clockwise and then pull the spray arm downwards and off.
After cleaning the spray arms screw them back into position.
After replacing the spray arms, check that they rotate freely.