Data transfer (optional)

Data transfer (optional)

The machine is equipped with an interface socket so that data can be transferred from Novotronic to a log printer.

Please contact Miele Technical Service to order printer cables.

The serial interface is RS 232 compatible.

Various printer types with Epson-compatible fonts can be used for printing.

Miele Technical Service maintains a list of recommended printers.

Pin assignment 9-pin sub-D connector:

5GND (ground)

3 TXD (send)

1-4-6 (bridge)

7-8 (CTS)

￿Printer initialization must only be performed by Miele. Consult Technical Service using the contact information on that back of this manual.

During program operation a protocol is prepared. It can be printed using an external printer.

The protocol contains the following information:

date and device number

program start time and name

rinse blocks used

dosage system with dosage temperature and target dosage amount

target values for temperature and holding times

minimal temperature during the holding time

all errors (e.g., water supply defect)

program end time

warnings, e.g., salt required.