Cleaning the drain pump and non-return valve

Cleaning and Care

Cleaning the drain pump and non-return valve

If water has not been pumped away at the end of a program the drain pump or the non-return valve may be blocked.

￿Turn off the machine.

￿Remove the filter combination out of the wash cabinet.

￿ Tilt the locking clamp to the side.

￿Pull out the non-return valve and rinse well under running water.

￿Use proper eye protection when removing the non-return valve.

The drain pump is beneath the non-return valve (see arrow).

￿Before refitting the non-return valve, check that the drain pump is not blocked. Spin the propeller several times in both directions to check for obstructions.

￿Carefully refit the non-return valve and secure it with the locking clamp. Refit and lock the filter in place.

For safety the load should be washed again.