Drainage

￿The drainage system is fitted with a non-return valve which prevents dirty water from flowing back into the machine via the drain hose.

￿The machine should preferably be connected to a separate drainage system onsite.

If separate drainage is not available contact Miele Technical Service for advice.

The onsite drain connection point should be located between 1 ft.

(0.3 m) and 3 ft. (1 m) above the lower edge of the machine.

If it is lower than 1 ft. (0.3 m), lay the hose in a curve at a height of at least 1 ft. (0.3 m).

The drainage system must be able to take a minimum drainage flow of

16 l/min.

￿The drain hose is approx. 5 ft.

(1.5 m), is flexible and has an internal diameter of 7/8 in. (22 mm). It must not be shortened. Hose clamps are supplied for securing it in position.

￿A longer drain hose (up to 13 ft. [4 m]) is available to order from Miele.

￿The drainage system must not exceed 13 ft. (4 meters).

￿See the supplied installation diagram.