Existing plumbing:

Installation

Existing plumbing:

If the standard 3/8" copper plumbing for a dishwasher already exists with a com- pression fitting and valve as pictured:

^Cut the 3/8" copper tubing after the valve.

^Install the 3/8" compression to 3/4" MHT (Male Hose Thread) adapter (supplied with the machine), as illus- trated.

^For any other size plumbing, pur- chase the correct size adapter from a hardware store.

^Connect the inlet hose to the existing valve/adapter assembly.

,Do not cut the intake hose. If the hose is cut, the dishwasher will not work. There will be a water leak and you could be injured. If the hose is too long, coil it neatly and place it behind the machine.

Electrical wiring and components should not come into contact with any plumbing fixtures or hoses.