Plumbing
All plumbing work should be carried out by a suitably qualified and competent person, in accordance with all applicable local and national regulations.
The manufacturer is not liable for damage to property due to an incorrect installation or water connection.
The water quality must conform to country requirements for drinking water.
–The appliance is only suitable for connection to the cold water supply.
–Water pressure
Maximum: 145 psi, if higher, install a pressure reduction valve.
–A separate
It must be easily accessible after the appliance has been
–Suitable 1/4" tubing or copper piping must be supplied for plumbing.
–To ensure the best ice cube quality, the maximum length of the tubing or copper pipe should not exceed 4 ft. 11" (1.5 m). If too much water remains in the tubing the quality could be affected.
Connecting the water supply
Before any installation or maintenance work is performed be sure the appliance is disconnected from the electrical supply.
Connection to the water supply should include a
^Remove the cover cap a from the solenoid valve b.
^Install the compression fitting c with the sealing ring d on the solenoid valve b.
^Attach the copper line e to the compression fitting c.
^Secure the copper line to the appliance using cable clips f.
39