Cleaning and care

Emptying the condensed water container

The condensed water will be collected in the condensed water container unless the dryer has been connected for external drainage (see "Installation").

Empty the condensed water container after every drying programme.

The Empty container indicator will light up if the maximum level of the condensed water container is reached. The indicator light will go out when the door is opened and closed again.

￿Pull out the condensed water container.

￿To prevent water running out, hold it at the front and towards the back and keep it in a horizontal position when carrying it.

￿

Empty the container.

￿

Replace the container in the dryer.

￿Condensed water should not be consumed. It could lead to health problems for people and animals.

Condensed water can be put to household use (e.g. in a steam iron or humidifier). To ensure that any residual particles of fluff in the condensed water are removed before use, pass it through a fine sieve or paper filter first.