9-7. Overload Protection (Kohler-Powered Units)

2

Located behind front panel.

Tools Needed:

3/8 in

4

3

YStop engine.

.When a circuit breaker or fuse

opens, it usually indicates a more serious problem exists. Contact a Factory Authorized Service Agent.

1 Circuit Breaker CB5

CB5 protects the 24 volt ac output to Remote receptacle RC4. If CB5 opens, 24 volt ac output to RC4 stops.

Press button to reset breaker.

2Fuse F2 (See Parts List)

3Fuse F6 (See Parts List)

F2 is located behind the front panel.

F2 protects the 115 volt output to Remote Receptacle RC4. If F2 opens, 115 volt ac output to RC4 stops.

F6 protects the engine wiring sys- tem from overload. If F6 opens, engine will not crank.

4Fuse F1 (See Parts List) Remove side panel.

F1 protects the exciter excitation winding from overload. If F1 opens, weld and generator power output stops.

Replace any open fuses. Reinstall cover before operating unit.